Skip to content

Development & Preliminary Testing

Compact, Flexible Fire Testing

  • Product development
  • Preliminary fire testing
  • Joint systems
  • Penetration seals
  • Small construction assemblies
  • Research programmes

Typical Configuration

  • Internal dimensions approx. 1.5 × 1.5 × 1.5 m
  • Vertical or horizontal specimen configurations
  • Fully automatic control with manual override, the same control philosophy as the full-scale furnaces
  • Temperature and pressure measurement; controlled extraction
  • Data acquisition and test documentation

Why Indicative

De-risk Certification Before Booking the Accredited Laboratory

Before committing to a full-scale official test at an accredited laboratory, manufacturers can validate expected performance with indicative tests, at a fraction of the cost and lead time.

  • Development furnace for iterating on product design before certification runs
  • Lower risk: catch failures early, before they cost a full-scale test slot
  • Mostly used for research and development of vertical and horizontal test specimens

Professional Measurement Principles

The indicative furnace can use the same fundamental measurement approach as larger installations, adapted to its size and intended test programme.

Temperature

Furnace and specimen measurement channels.

Pressure

Controlled pressure measurement and extraction.

Documentation

Test data can be organized with DataBrain for observations, timeline and report preparation.

Performance

  • Fully automatic control with manual override
  • Temperature and pressure measurement; controlled extraction
  • Curve library shared with the full-scale furnaces; curves and maximum temperature specified per project

Refractory and Steel

  • Pre-cast, pre-cured refractory concrete blocks: long service life, rapid repair without full relining
  • Side walls in JM 23 / JM 28 insulating brick, backed by Ca-Si plates; roof and floor in low-thermal-mass, high-temperature concrete
  • Fabrication to EN ISO 3834-2; all structural welds 100 % NDT tested; sandblasted and primer-coated
  • Engineered thermal expansion margins prevent deformation during heating
  • Minimized heat loss, so energy consumption per test and NOx emissions are lower

Indicative Furnace References

  • Country
    United Arab Emirates
    Laboratory
    Safety laboratory, Dubai
    Scope
    Complete laboratoryComplete laboratory: concept, design, commissioning and technician training
    Equipment
    Indicative furnaces within a complete laboratory with vertical and horizontal furnaces and load frames
All references

Request Information

Discuss Your Project

Contact STARKOS to define your test programme, standards, specimen dimensions, instrumentation and laboratory requirements.